Instrument calibration control
Arrange calibration with your providers, review certificates, and decide when equipment can return to use. Keep owners and quality reviewers on the same records.
Free for up to five users. No credit card required.
Adapt fields, workflows, and dashboards without code. Explore 1,000+ app templates and use cases
Preview with sample data. Sign in to explore or install the app.
Follow the instrument through four separate decisions, with the original evidence and responsible reviewer visible at each handoff.
The equipment owner selects the instrument and requests a window. The coordinator confirms the provider and timing, taking access and replacement needs into account.
Match the certificate to the serial number and required scope. Keep as-found (before adjustment) and as-left (after service) results separate, then review the next due date.
Identify potentially affected work, containment, action owners, and disposition. An adjustment followed by a passing result does not erase the earlier failure.
In a separate review task, the assigned reviewer records the allowed use and date. Current service, accepted evidence, unresolved impacts, and due-date validity are checked before the decision.
After signing in, explore the sample before installing your own copy. Start with the work you would need to explain to a colleague.
Open Instrument status and find the torque wrench tagged ASM-TQ-008. Switch to Tool history and select that equipment tag to inspect the result and related decisions. The as-found failure remains visible even though the as-left result passed.
In an installed copy, open New service request and select an instrument. Add proposed timing and replacement needs; the coordinator then reviews the arrangement. Configure your members and review responsibilities before using the app for real work.
Missing certificate → evidence returned for correction → corrected file retained → unresolved impact cases still blocked use authorization → completed reviews updated the exact instrument. The checks used one authorized administrator with fictional data; they do not certify your team’s access controls.
A dashboard is useful when each status leads to a specific record and next action.
| What you see | What it means | What to do next |
|---|---|---|
| A due date is approaching | There is still planning work to do, even if the instrument is currently released. | Check provider lead time, downtime, replacement availability, and the requested service window. |
| Certificate awaiting review | The instrument or file may have returned, but the evidence has not been accepted. | Open the result, check identity and scope, and return incomplete evidence for correction. |
| As-found failure with an as-left pass | The instrument was adjusted or corrected, but earlier work may still need assessment. | Review affected work and document containment and disposition before considering release. |
| Awaiting return to use | An evidence or impact review has progressed; use authorization is still a separate task. | Inspect current evidence and all linked impact cases, then record the authorized scope. |
The same equipment number connects the work. Separate records preserve what was requested, what was found, and who made each decision.
Current accepted result, reviewed due date, use status, and linked history.
Requested and confirmed dates, service reason, provider, and replacement arrangements.
Original certificate, scope check, as-found and as-left outcomes, and acceptance.
Affected work, containment, action ownership, and documented disposition.
The accepted evidence, permitted use, reviewer decision, and authorization date.
Your provider changes from collection to on-site visits. The coordinator now needs access instructions, a contact, and a replacement-tool plan. Add these to the request and keep the existing instrument and certificate histories intact.
Critical torque tools need an additional quality review after an as-found failure. An authorized administrator can adjust the native task routing and review fields. Check both a blocked case and a correctly completed case before using the changed process.
It fits teams that receive calibration from qualified providers and need a process that can change with equipment categories, sites, and responsibilities. Forms, linked records, review tasks, and dashboards stay in one configurable application.
If you need automated test procedures, documenting-calibrator communication, uncertainty calculations, or laboratory certificate production, assess specialist calibration software. Jodoo can coordinate related business work, but this app does not replace those functions.
No. This app coordinates instruments, service arrangements, evidence review, and use authorization. Measurements, uncertainty calculations, and technically valid calibration results remain with your qualified provider or specialist calibration system. Attach the original evidence and have an appropriately qualified reviewer assess it.
Yes. Use a common instrument identity and location fields, then configure views for each site. Decide separately who can read and change each site’s records: a filtered dashboard is not an access restriction. The example does not come with your locations, member assignments, or site-specific permissions already established.
Update the responsible member for future work and inspect tasks already in progress. Do not assume a new owner automatically receives every existing review. Use the appropriate task-transfer or reassignment action, retain the earlier decisions, and confirm the next responsible person can see the open work.
Not for your internal coordinator to record a service arrangement and attach a certificate received from the provider. The sample is an internal equipment-control app, not a preconfigured supplier portal. Direct provider submissions require a separately designed access and intake process; do not share internal reviewer permissions with a supplier.
No. It is a configurable business application with fictional sample records. Your organization must establish its procedures, responsibilities, access controls, technical review, and any required validation. Neither an app status nor an uploaded file establishes metrological traceability or permission to use real equipment.
Open the sample instrument register, choose a restricted tool, and follow its certificate and review history. Install a copy when you are ready to configure your team’s process.